IP55 Telecom Cabinet SNMP Function Heat Exchange for Computer Room Outdoor Use
Brief Information
1. Computer room heat exchanger
2. Cooling capacity:1200W/k
3. Air volume:6000m3/h
4. CE and RoHs certification
product name: outdoor network cabinet
1. Computer room heat exchanger
2. Cooling capacity:1200W/k
3. Air volume:6000m3/h
4. CE and RoHs certification
Introduction
HEU-S Series Base Station cabinet air exchaner system is specially design for mobile, telecom stations or computer room, etc, mainly used to eliminate the heat in the base station. The outdoor cold air after the purification, directly introduce into the equipment, then exchange the heat with exhaust air through the sensible heat recovery unit, expel heat from the equipment.
So as to cool the equipment, reduce the consumption of energy, and not only provide an ideal temperature and humidity environment for the cabinet air exchanger system, but also separate the dust and moisture from the equipment, greatly extend the service life of electronics parts and improve the system reliability.
Feature
Energy Saving
It real-time control monitoring the inside and outside temperature ,when the outside temperature is lower to a certain extent, the equipment will begin to work, remove the inside heat to outside, so as to reduce the air-conditioner working time and save the energy.
Water And Dust Proof
Enclosed air circuit cooling system , completely isolate the inside and outside air, effectively avoid air contamination from outside.
Several Working Models and Standard RS485/RS232 Intelligent Control
Function
Setting the parameter for automatic protection, when the unit power outage, computer can record the parameter and outage information, after the power on, it will work again follow the status before the power outage ,it have the time delay function, to avoid power flash affect the unit or automatic trip.
Air-conditioner Troubleshooting
When base station air conditioner goes wrong,the equipment remove the inner heat to outside in time, make sure the electron devices working well.
Protection Warning Function and Stable performance
High quality accessories and less moving parts, so as to reduce the machine fault and easy to maintenance.
Specifications
Internal capacity | 19" RACK |
Weight | ≤80kg (without rectifier module and battery) |
Panel material | 304 stainless steel cabinet |
Installation mode | On groundWall mountedPole mounted |
Input voltage | -48V |
Operating temperature | -40℃~+55℃ |
Operation humidity | 5%~100% |
Battery space | 8U (100AH) |