Model: | 24/ 1000 SIL3 OVP | Part Number: | 241122.290 |
---|---|---|---|
Efficiency @ Nominal Input: | 92.50 % | Voltage (nominal): | 230 V AC/ DC |
Voltage (full Power): | 185 - 275 V AC/ DC | MTBF: | >300 000 (@ T Ambient : 25 °C) |
Electrical Safety: | UL 60950-1, EN 60950-1, IEC 61508 | Acoustic Noise: | < 46dBA At Nominal Input And Full Load |
High Light: | telecommunication network equipment,network communication equipment |
241122.290 1000W SIL3 OVP Eltek Flatpack S 24V 1000W Rectifier
Specifications
Model | 24/ 1000 SIL3 OVP |
Part number | 241122.290 |
INPUT DATA | |
Voltage (nominal) | 230 V AC/ DC |
Voltage (full power) | 185 - 275 V AC/ DC |
Voltage (full power, reduced power factor) | 275 - 305 V AC/ DC |
Voltage (reduced power, linear de-rating) | 85 - 185 V AC/ DC |
Frequency (nominal / range) | 45 - 66 Hz / 0 Hz |
Current (maximum) | 5.9 A RMS |
Power Factor | > 0.99 at 50% load or more |
Protection | Fuse and Shutdown above 305 V AC / 300 V DC and below 85V AC/ DC |
OUTPUT DATA | |
Voltage (default) | 26.7 V DC |
Voltage (adjustable range) | 21.5 - 28 V DC |
Power (maximum) @ nominal input | 1000 W |
Power @ 85 VAC | 420 W |
Current (maximum) @ nominal input | 41.7 A (@V OUT < 24 VDC) |
Current sharing (10 - 100% load) | ±5% of maximum current from 10 to 100% load |
Static Voltage regulation (10 - 100% load) | ±0.5% |
Dynamic Voltage regulation | ±5.0% for 10-90% or 90-10% load variation, regulation time < 50ms |
Hold up time | >20ms; output voltage > 41 V DC |
Ripple | < 200 mV peak to peak, 30 MHz bandwidth |
Protection | Blocking OR-ing Diode, Short circuit proof and High temperature protection |
Overvoltage protection, SIL3 parameters |
Protection level: 30V • PFD = TBS Proof test interval: 15 years • SFF = TBS Handles dual component failure |
OTHER SPECIFICATIONS | |
Efficiency @ nominal input | 92.50 % |
Isolation | 3.0 kVAC - input to output, 1.5 kV AC - input to earth & 0.5 kV DC - output to earth |
Alarms: Red LED |
Low mains shutdown, High and low temperature shutdown, Rectifier Failure, Overvoltage shutdown on output, Fan failure, Low voltage alarm, CAN bus failure |
Warnings: Yellow LED |
Rectifier in power derate mode, Remote battery current limit activated, Input voltage out of range, flashing at overvoltage |
Normal operation: Green LED | |
Potential alarm relay (normally open) |
Opens on alarms, mains outage and >40% loaded (ensures redundancy in 1+1 system) when not connected to a controller |
Normal (module running): Green LED 'on' | |
Acoustic noise | < 46dBA at nominal input and full load |
MTBF (Telcordia SR-332 Issue I method III (a)) | >300 000 (@ T ambient : 25 °C) |
Operating temperature |
-40 to +85°C ( -40 to +185°F), humidity 5 - 95% RH non-condensing Output power de-rates linear from 1000W @ 45°C (113°F) to 400W @ 85°C(185°F) |
Storage temperature | -40 to +85°C (-40 to +185°F), humidity 0 - 99% RH non-condensing |
Dimensions[WxHxD] / Weight | 72 x 41.5 x 210mm (2.83 x 1.63 x 8.27”) / < 1 kg (2 lbs) |
DESIGN STANDARDS | |
Electrical safety | UL 60950-1, EN 60950-1, IEC 61508 |
Marine | DNV-OS-D202, Ch.2 Sec.4 (DNV2.4): Temperature Cl.B, Humidity Cl.B, Vibration Cl.A, EMC Cl.B1) IEC 60945-4th edition |
EMC |
ETSI EN 300 386 V.1.4.1 EN 61000-6-1 / -2 / -3 / -4 / -5 FCC Part 15 Subpart 109 |
Environment |
ETSI EN 300 019: 2-1 (Class 1.2), 2-2 (Class 2.3) & 2-3 (Class 3.2) RoHS (2011/ 65/ EU) and WEEE (2002/96/ EC) compliant |
1) Class B requires external filter on input (p/ n 241120.930) |
Overview
Compact HE rectifiers for marine, offshore and process industry applications
Applications in these markets demand state of the art, reliable and safe DC power systems. Flatpack S delivers an industry leading power density in its segment, many safety functions, wide operating temperature range and superb reliability in its small 210mm deep housing.
The Flatpack S 24/ 1000 SIL3 OVP is targeted Safety and Automation Systems (SAS) in offshore and process industry requiring SIL rated overvoltage protection on DC output.
Used in the 3U rack with Smartpack S controller, the Flatpack S rectifiers cover 2 to 8kW applications using a minimum of space, less than 18 liters, and low heat dissipation.
Features
Small
Short
Power Dense, 26 w / Cu In
High Efficiency
Oring Protection On Output
Sil3 Rated Overvoltage Protection On Output
Hot Pluggable
Voltage Keying
Application
Offshore And Process Industry
Safety And Automation Systems (SAS)
3 TIMES 2 RECTIFIERSSYSTEM IN A 3U RACK
SMARTPACK S CONTROLLER
8 RECTIFIERS 3U SYSTEM -BULK OUTPUT
FLATPACKS 24V 1000W EFFICIENCY PLOT